Abstract

Understanding dislocation variability in complex proximal femur fractures and the relationships with the pattern of fractures may play a crucial role in choosing the right type of implant. Comminution of the intertrochanteric area, incompetency of the lateral wall and trochanteric support are difficult to evaluate on plain X-rays and sometimes even in CT. Most of the complications belong to typical fracture patterns: A3 and so-called “reverse” A2 in AO classification. Cefalo Medullary Nails (CFN) may not be superior to Sliding Hip Screw plates (SHS) in peculiar type of fractures lacking lateral buttresses able to restrain the lateralization of the proximal head-neck fragment. Lateral trochanteric support and antirotational device in the head-neck complex may reduce secondary dislocation, non union or hardware failure complications. In this paper, a correlation between osteo-synthesis and stability of the metal-bone construct is discussed.

Lateral complex fractures

The most important criteria, beyond A2 and A3 AO classification, to qualify complex fractures are the comminution and/or dislocation of fragments that are able to compromise the stability of the hardware-bone construct.

Major complication rates are related to: peri- and intratrochanteric comminuted fractures, dislocation of the medial wall (including the lesser trochanter), weak lateral buttress, inter-fragmentary instability after reduction or irriducibility 1-3. These radiographic key points are often difficult to assess on standard Rx obtained in emergency 1.

AO A3, so called “inverse intertrochanteric” fractures present lateral wall incompetency. The great trochanter is often displaced and fracturated and the head-neck complex presents a poor contact with lateral proximal structures (great trochanter and lateral wall). Diaphyseal extension from the proximal fracture site adds even more instability and reduction problems to this type fractures (Fig. 1).

Problems with fixation and secondary displacement

Weight-bearing and antigravity movements can jeopardize the stability of the bone-metal construct 1,4,5. There are primarily 3 types of solicitations over the construct concurring to a secondary dislocation:

  1. Rotation of the head-neck complex: if the intertrochanteric area is comminuted and there is a poor contact between head-neck fragment and lateral structures, the rotation of the head-neck complex will increase the varus deformity and telescopage with impaction. The combination of rotational and axial solicitations will increase the risk of cut-in and cut-out of the dynamic cervical screw or blade.
  2. Lateral compaction: usually occurs when the intertrochanteric area is comminuted. A relative shortening of the femoral neck compacting the rhyme may be useful to stabilize the fracture site and to prevent stress failure over the implant, however an eccessive shortening (over 20 mm or 1/3 of the femoral neck) will change the lever of the medium gluteus, resulting in a Trendelemburg effect, and limping. Excessive lateral impaction in early follow-up X-rays, arouses suspicions when the lateral trochanteric structures are disruped: it can lead to a progressive lateral translation, cut in and hardware failure.
  3. Lateral shifting: it may occur when the entire lateral buttress of the proximal femur is interrupted and the intertrochanteric area is comminuted 1,2,4,6. Great trochanter and lateral wall result ineffective. The final effect is an excessive lateral compaction with telescopage and sliding. High bending and torsional forces concentrate over the implant increasing the risk of hardware failure.

Considerations on implants

Sliding hip screw plates (SHS) and cephalo-medullary nails (CMN) are widespread fixation systems for the treatment of proximal femoral fractures. Few (mainly nails) present a double screw fixation system in the neck-head area. Distal static or dynamic blockage is available in almost all CFN, while dynamic features of extramedullary systems rely only on proximal sliding screw(s).

In the last 20 years, most orthopedic surgeons grew up discussing about superiority of CMN in the treatment of “unstable” lateral proxinal femoral fractures 2,4,6. While SHS plates usually do not provide any restrain in the upper trochanteric area, indeed the proximal intertrochanteric-metaphyseal segment of a CMN acts as a buttress against the lateralization of the neck-head complex 1,2,4,6. However, the disruption of the trochanter, intertrochanteric area and lateral wall, may lead to an unpreventable lateral dislocation “around“ the nail.

For some SHS plates a proximal extension stabilizing as an external buttress the trochanter. Some pioneering systems with an extra-medullary plate connected to a CMN have been recently proposed 7.

Discussion and conclusions

“Lateral complex” fractures of the proximal femur are at a high risk of complications. To prevent secondary dislocation some precautions have to be considered:

  1. to neutralize rotational dislocation of the head-neck fragment, a double-barrel screw system in the may performs better than a single screw system. The role of anti-rotational device – as far as useful to increase the rotational stability – is still to be specified (eg. spiral blade – Synthes TM or u-blade – Stryker TM).
  2. CMNs act as a buttress in the intertrochanteric and metaphyseal area, and as such are useful to prevent excessive telescoping and shortening 1-3, but, in case of intertrochanteric comminution and lateral buttress disruption, they may be ineffective.
  3. once trochanter dislocation and lateral wall are disrupted, an extramedullary plate support may be useful to reduce the lateral shifting of the head-neck complex. If the diaphyseal extension of the fracture involves the lateral wall at the transition between trochanter and diaphysis, reduction and fixation of the diaphyseal fragment reduces the possibility of lateral shifting.

Figures and tables

Figure 1.“Inverse” intertrochanteric fracture with diaphyseal extension.

Figure 2.There is no fixation of the lateral structures. High stress forces are concentrated on the nail to prevent secondary dislocation.

Figure 3.Areas in proximal femur related to implants (from Regazzoni et al., 2018, mod.) 1.

Figure 4.Lateral sliding “z” effect and hardware failure in lateral structure breakage.

References

  1. Regazzoni P, Fernández Dell’Oca A, Berlusconi M. Description and understanding of proximal femur fractures using coloured 3D models. ICUC. 2018.
  2. Bredbenner TL, Snyder SA, Mazloomi FR. Subtrochanteric fixation stability depends on discrete fracture surface points. Clin Orthop Relat Res. 2005; 432:217-25.
  3. Strauss E, Langford JR, Baumgartener MR. Current concepts offered for managing geratric intertrochanteric hip fractures. Orthopedics Today. 2017.
  4. Roberts CS, Nawab A, Wang M. Second generation intramedullary nailing of subtrochanteric femur fractures: a biomechanical study of fracture site motion. J Orthop Trauma. 2002; 16:231-8.
  5. Bergmann G, Deuretzbacher G, Heller M. Hip contact forces and gait patterns from routine activities. J Biomech. 2001; 34:859-71.
  6. Crawford CH, Malkani AL, Cordray S. The trochanteric nail versus the sliding hip screw for intertrochanteric hip fractures: a review of 93 cases. J Trauma. 2006; 60:325-9.
  7. Shashikant BG, Wasudeo MG, Pradeep K. Trochanteric buttress plate combined with proximal femoral nail for unstable intertrochanteric fractures. [Innovative technique]. Medicine. 2018; 8:235-47. DOI

Affiliations